MODEL | T-120A | T-120B | T-120C | T-120D | ||||||||
DC VOLTAGE | 5V | 12V | -5V | 5V | 12V | -12V | 5V | 15V | -15V | 5V | 12V | 24V |
RATED CURRENT | 11A | 5A | 1A | 11A | 4.5A | 1A | 10A | 3.5A | 1A | 8A | 2.5A | 2A |
CURRENT RANGE | 2-12A | 0.5-5A | 0.2-1A | 2-12A | 0.5-5A | 0.2-1A | 2-12A | 0.5-5A | 0.2-1A | 2-12A | 0.2-5A | 0.2-2A |
RATED POWER | 120W | 121W | 117.5W | 118W | ||||||||
RIPPLE & NOISE (max. ) | 80mVp-p | 120mVp-p | 80mVp-p | 80mVp-p | 120mVp-p | 120mVp-p | 80mVp-p | 150mVp-p | 150mVp-p | 80mVp-p | 120mVp-p | 180mVp-p |
VOLTAGE ADJ. RANGE | CH1: 4.75 ~ 5.5V | |||||||||||
VOLTAGE TOLERANCE | ± 2.0% | ± 6.0% | ± 6.0% | ± 2.0% | ± 6.0% | ± 6.0% | ± 2.0% | +10-5% | +10-5% | ± 2.0% | ± 6.0% | ± 6.0% |
LINE REGULATION | ± 0.5% | ± 1% | ± 1% | ± 0.5% | ± 1% | ± 1% | ± 0.5% | ± 1% | ± 1% | ± 0.5% | ± 1% | ± 1% |
LOAD REGULATION | ± 1% | ± 5% | ± 5% | ± 1% | ± 5% | ± 5% | ± 1% | ± 5% | ± 5% | ± 1% | ± 5% | ± 5% |
SETUP, RISE, HOLD TIME | 800ms, 20ms, 20ms/230VAC 1600ms, 20ms, 12ms/115VAC at full load | |||||||||||
VOLTAGE RANGE | 88 ~ 132VAC / 176 ~ 264VAC selected by switch 240 ~ 370VDC | |||||||||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||||||
EFFICIENCY (Typ. ) | 77% | 77% | 76% | 80% | ||||||||
AC CURRENT | 2.8A/115VAC 1.6A/230VAC | |||||||||||
INRUSH CURRENT (max. ) | COLD START 35A | |||||||||||
LEAKAGE CURRENT | < 3.5mA / 240VAC | |||||||||||
OVERLOAD | 105 ~ 135% rated output power. | |||||||||||
Protection type: Shut down o/p voltage, re-power on to recover. | ||||||||||||
OVER VOLTAGE | CH1: 5.75 ~ 6.75VDC | |||||||||||
Protection type: Shut down o/p voltage, re-power on to recover. | ||||||||||||
WORKING TEMP. | -10 ~ +60º C | |||||||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||||||||
STORAGE TEMP., HUMIDITY | -20 ~ +85º C, 10 ~ 95% RH | |||||||||||
TEMP. COEFFICIENT | ± 0.03%/º C (0 ~ 50º C) | |||||||||||
VIBRATION | 10 ~ 500Hz, 2G 10min. /1cycle, 60min. each along X, Y, Z axes | |||||||||||
SAFETY STANDARDS | Design refer to UL1012 | |||||||||||
WITHSTAND VOLTAGE | I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC | |||||||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC | |||||||||||
EMI CONDUCTION & RADIATION | Compliance to EN55022 (CISPR22) Class B | |||||||||||
HARMONIC CURRENT | Compliance to EN61000-3-2, -3 | |||||||||||
EMS IMMUNITY | Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11; ENV50204, EN55024, Light industry level, criteria A | |||||||||||
MTBF | 274.5K hrs min. MIL-HDBK-217F (25º C) | |||||||||||
DIMENSION | 199*110*50mm(L*W*H) | |||||||||||
PACKING | 0.80Kg; 16pcs/13.36/0.0287CMB |