Customization: | Available |
---|---|
Type: | Reflective Panels Type Photoelectric Sensor |
Output Signal Type: | Analog Type |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Mounting way | Diffuse type | |||
Type | DC type/span> | NPN | NO | E3F3-R4NK |
NC | E3F3-R4N2 | |||
NO+NC | E3F3-R4N3 | |||
PNP | NO | E3F3-R4PK | ||
NC | E3F3-R4P2 | |||
NO+NC | E3F3-R4P3 | |||
Two-wire | NO | |||
NC | ||||
AC type | Two-wire | NO | E3F-R4Y1 | |
NC | E3F-R4Y2 | |||
Three-wire | NO+NC | |||
Delection range | 4m ± 10% | |||
Delection range regulation | Sensitivity adjuster | |||
Response frequency | DC:0.5kHz AC:25kHz | |||
Supply voltage |
DC type:DC12-24V(6-36V)Impulse AC type:AC110-220V(90-250V)50/60Hz |
|||
Withstand voltage | AC 1000V 50/60HZ 1min between charging part and housing | |||
Voltage influence | side ±15% rated supply voltage range, at rated supply voltage value, inside ±10% detection distance | |||
Consumption current | N.P type:13mA below, D type:0.8mA below, A type:1.7mA below below,A type:1.7mA below | |||
Control output | N.P type: 300mA below,D type:200mA below,A type:400mA below | |||
Loop protection | N.P.D type: reversal connection protection,surge absorption,load short-circuit protection,A type:surge absorption | |||
mbient temperature & humidity |
During operation,storage:individually-30~+65ºC (no freeze,no drew),During operation, storage:individually 35~95%RH |
|||
Temperature influence |
Temperature range -30-+65ºC,at+23ºC, ±15%detection distance Temperature range -25-+60ºC,at+23ºC, ±10%detection distance |
|||
Insulation impedance | 50MΩ above(DC500 megameter)between charging part and housing | |||
Material | Housing:Nickel plated brass Detection surface:ABS | |||
Protection level | IP67( IEC specification) |